Seta Multi Filtration Tester (MFT), 91600-3

The Multi Filtration Tester (MFT) fully conforms to the latest ‘cold soak’ filterability test requirements for FAME and bio diesel. It is a unique and versatile instrument designed to test the Filter Blocking Tendency (FBT) of diesel, biodiesel (B100 & B5/7/20/30), gas oil, gas turbine fuel and kerosene. Test parameters for IP 387 and ASTM D2068 are pre-programmed. FBT analysis is achieved by measuring the pressure differential across a disposable filter. Fuels which have a high FBT could potentially block filters in the distribution network or during use in a vehicle or power plant.

MFT is also used to determine the FBT for BX fuels containing bio components, such as FAME (biofuel), which have been ‘cold soaked’ at a temperature just above zero Celsius. During the 16 hour cold soak particles of saturated monoglycerides (SMG’s) and sterol glucosides can be formed which do not dissolve when the temperature is raised back to ambient.

Methods: ASTM D2068, CEN N403, EN 590, IP 387, IP PM EA/08

MFT is microprocessor controlled and provides a simple user interface using 2 buttons and the Seta Multifunctional And Rotational Test (SMART) control feature in conjunction with a backlit alphanumeric 4 line display. The SMART control is exceptionally easy to use for selecting different tests, setting parameters and for calibration of the temperature and pressure sensors. The display provides the operator with test procedure information as well as indicating the selected test method, sample temperature, pressure, volume and the test result.

A printer can be connected to provide a permanent record of the test parameters, results and a filterability graph. The software permits the operator to set the test volume of liquid up to 1 litre and a maximum pressure of 200kPa. This allows both specification testing and gravimetric tests to be carried out in conjunction with the appropriate filters and holders.

The fuel sample is drawn from the integral fuel reservoir by the pump, and an efficient pulse damper provides smooth and continuous flow. The pressure and temperature of the fuel are continuously monitored while it is pumped through the specified filter into the waste container. The recorded pressure rise, or the volume of pumped sample that causes a specified pressure to be exceeded, are used by the microprocessor to calculate the test result. Standard tests use 300ml of fuel pumped at 20ml/min.

Verification and re-calibration is simple but secure. The Setalert accessory can be used to alert an operator of the end of the test at distances up to 300 metres.

Supplied with: filter forceps, mains lead, fuel beakers and instruction manual

  • Portable test for filterability/blocking tendency of Fuel Oils
  • Testing of Bio components including FAME material and cold soak testing
  • Easy to use, fully automated operation
  • Large LCD display
  • Results in less than 15 minutes
  • Automatic calculation of FBT and F-QF
  • Simple calibration/verification of flow, pressure & temperature
  • Interface for PC/Printer
  • Filter housing & filter packs are available according to test method requirements
Filter blocking tendency (FBT) range 1.0 to 30 (low number is best)
Filterability quality factor (FQF) range 100 to 1 (high number is best)
Maximum pressure 200kPa
Power supply 110/120V, 50/60Hz 220/240V, 50/60Hz (switchable)
Power 500W
Size (HxWxD) 27 x 43 x 26cm
Weight 10kg
CCCN Code: Tariff 90268080