Setaflash Series 3 Plus Flash Point Tester, 33000-2

Similar operation to 30000-2 model but with the additional feature of an automatic ‘Ramp’ mode. The temperature ramp mode is ideally suited for unknown samples and allows rapid determination of the flash point of a sample in accordance with ASTM D7236 and IP 534. The cup is heated at a rate of 2°C per minute from the start temperature. An audible prompt to carry out a flash test occurs every 1°C rise up to 100°C, every 2°C rise over 100°C.

  • Compliance
  • Safety
  • Product quality
  • 2ml of sample and a result in less than 2 minutes

Setaflash Series 3 Plus has a very simple user interface with colour digital display and touch screen icons which guide the operator through a straightforward testing process.

For easy record keeping the instrument stores 100,000 test results which can be saved and transferred via a USB port.

The versatile range of Setaflash instruments is ideal for use in the laboratory, production line or for portable test applications.

Methods: ASTM D3278, ASTM D3828, ASTM D7236, ASTM E502, BS EN ISO 3679, BS 2000-523, Classification of Dangerous Goods for Carriage: Viscous and Non-viscous Liquids, CLP Regulations EC No 1272/2008, DEF STAN 91-91, EPA 1020 A & B, IP 523, IP 524 (Obs), IP 534, ISO 3680 (Obs), UN Class 3 Non-viscous Flammable Liquids

Rapid Results in just 1 or 2 minutes The Setaflash Series 3 Plus is an easy to use instrument that can complete a flash/no-flash test in less than two minutes and in many cases in 60 seconds, or search for flash point of a sample within a temperature range of 0°C to 300°C.

Ease of Operation All functions on the Series 3 Plus including test parameters, instrument status and test results are accessed via the touch screen display and push button. An audible prompt is sounded when a flash is achieved. An automatic flash detector reduces the chance of misinterpretation of the test result by the operator and enhances repeatability.

Innovative Design Gas for the test jet/shutter assembly is supplied from an integral gas tank, which is filled using a standard butane (lighter) refill cartridge. The Series 3 Plus Flash Point Tester is lightweight and suitable for mobile use when operated from the optional 12 volt power supply adaptor. Supplied with: 2ml syringe, ignitor, mains lead and instruction manual.

  • Ambient to 300°C
  • Flash point test in less than 2 minutes
  • Small sample size – 2 or 4ml
  • Flash/no Flash or Ramp mode
  • Automatic flash detection
  • Automatic barometric pressure correction
  • USB port & results storage
  • Colour touch screen
  • Cost effective
  • Portable operation
  • Simple calibration
Temperature range Ambient to 300°C
Temperature ramp mode Automatic or custom settings (ramp rate: up to 6°C/min and beep rate: up to 5°C/B intervals). Extended test range, 100°C from start temperature
Temperature selection °C or °F
Cup material Aluminium
Gas supply Integrated gas tank (removeable)
Pressure correction Automatic barometric correction
Voltage 110 to 250V a.c~50/60 Hz (universal)
Power 200W (Max.)
Size (HxWxD) 21 x 28 x 14cm
Weight 3Kg
CCCN Code: Tariff 90268020

Lazar Scientific is your reliable source for Flash Point Testing Equipment.