Clora – 400641-01M

Clora – 400641-01M

Chlorine Analysis in Liquid Hydrocarbons, Aqueous Solutions, and Catalyst

Clora benchtops are compliant with ASTM D7536 and D4929 standards and deliver a limit of detection of 0.13 ppm and a dynamic range of up to 3000 ppm. Clora is powered by MWDXRF, the same technology found in our signature sulfur analyzer, Sindie. This direct measurement technique does not require gasses or high-temperature processes equating to easy operation and minimum maintenance requirements.

Methods: ASTM D7536, D4929

Features

This model utilizes standard XRF sample cups.

  • Easy to use
  • Extremely low maintenance
  • Total chlorine analysis
  • For use in multiple application areas
  • Hassle-free sample prep

Easy to use
User-friendly with a touch screen interface. Just plug-it-in and measure results with one touch: power is only utility.

Extremely low maintenance
No conversion gasses, columns, heating elements, or quartz tubing

Total chlorine analysis
Aqueous solutions and aromatic products to heavy fuels, crudes, and catalysts.

For use in multiple application areas
Refinery labs, pipeline terminals, additive plants, testing vans, and inspection laboratories

Hassle-free sample prep
Utilizes standard XRF sample cups.

Accu-flow: No
Calibration curves: 8 calibration curves. Automatic and Manual Calibration functionality.
Catalysts: No
Communication Capabilities: Printer, Ethernet: LIMS Connectivity (optional)
Concentration: In ppm: 0.05, 1, 5, 10, 50
Consumable/Utility Gas: Vacuum
Dimensions: Depth: 19.7 in / 50.0 cm
Dimensions: Height: 13.4 in / 34.0 cm
Dimensions: Width: 14.6 in / 37.0 cm
Element: Chlorine / 0.13 ppm
Measurement Time: User selectable 30 – 900 s, 300 – 600 s typical
Method Name: ASTM D7536 & D4929
Options: LIMS Connectivity
Range: 0.13 ppm – 3000 ppm
Repeatability: ppm – r
Xylene
0.05 – 0.15
1 – 0.17
5 – 0.31
10 – 0.50
Crude Oil
5 – 0.4
10 – 0.8
50 – 1.2
Water
5 – 0.6
10 – 1.0
50 – 1.5
Reproducibility: ppm – R
Xylene
0.05 – 0.27
1 – 0.29
5 – 0.53
10 – 0.90
Crude Oil
5 – 0.7
10 – 1.4
50 – 2.0
Water
5 – 1.0
10 – 1.5
50 – 2.5
Sample Cup Type: Standard XRF Cup
Sample Matrix: Hydrocarbon
Specific Technology: MWDXRF
Type: Benchtop
Weight: 70 lbs / 32 kg
What’s included?: Quick-Start Guide, Operations Manual, radiation survey, power cord, 6′ drain tubing, spare fan filter, printer, printer cable, printer ink, 1 roll of printer paper, spare fuse, 100 sample cups, 100 sample films, sample stand, spare primary window, and 1 calibration set; 0-500 ppm Cl in Mineral Oil (6 x 10 mL).
XRF Film Type: Etnom

Clora Models Available

CLORA MODELDESCRIPTIONAUTO-SAMPLERACCU-FLOWCATALYSTS
Clora – 400641-01MThis model utilizes standard XRF sample cups.
Clora with Autosampler – 401430-01MThis model features an 8-cell autosampler and utilizes Accucell sample cups for hassle-free sample prep.Check Mark
Clora Accu-flow – 400641-01MFTThis model features Accu-flow to eliminate particle settlement during analysis. For best results, use standard XRF cups with static sample measurement, and Accucell cups with Accu-flow.Check Mark
Clora with Accucell – 400641-02MThis model utilizes Accucell sample cups for hassle-free sample prep.
Clora Extended Range – 400641-01MXRThis model features an extended range from 0.13 ppm – 4 wt%, and utilizes standard XRF sample cups.
Clora Extended Range with Autosampler – 401430-01MXRThis model features an extended range from 0.13 ppm – 4%, an 8-cell autosampler, and utilizes Accucell sample cups for hassle-free sample prep.Check Mark
Clora Extended Range with Accu-flow – 400641-01MXRFTThis model features an extended range from 0.13 ppm – 4 wt%, and Accu-flow to eliminate particle settlement during analysis. Utilize standard XRF cups with static sample measurement, and Accu-cell cups with Accu-flow.Check Mark
Clora Extended Range (Catalysts) – 400641-01MXRCThis model features an extended range from 0.13 ppm – 4 wt% (measures catalysts), and utilizes standard XRF sample cups.Check Mark
Clora Extended Range (Catalysts) with Accu-flow – 400641-01MXRCFTThis model features an extended range from 0.13 ppm – 4 wt% (measures catalysts), and Accu-flow to eliminate particle settlement during analysis. Utilize standard XRF cups for static sample measurement, and Accucell cups for Accu-flow.Check MarkCheck Mark