FIJI MF – FAME in MultiFuels – SA5200-0
The patented FIJI has been developed to offers a rapid and easy check on Parts Per Million (ppm or mg/kg) levels of FAME in aviation fuel, distillates, residuals, and gasoline.
FIJI uniquely utilizes FTIR (Fourier Transform Infra-Red Spectroscopy) technology and a patented sample preparation system which allows FAME detection accuracy down to the 10 mg/kg level.
FIJI can be used as a field or lab-based screening tool to give a quick indication of possible FAME contamination that may then necessitate further investigations. The instrument helps to prevent expensive testing and avoid costly delays of fuel release.
Methods: ASTM D1665, ASTM D7797, ASTM D7963, IP 583, DEF STAN 91-091, ISO 8217
Features
- 10-150ppm (mg/kg) in Jet Fuels
- 20 mg/kg to 20% in Distillate & Residual Fuels
- Measures the presence of all FAME types C8 to C22
- Approved for co-processed fuels
- No hydrocarbon cleaning solvents required
- Laboratory and field instrument
- Suitable for untrained operators
- Patent Approved
Ease of use:
The instrument is extremely simple to use and fully automatic, specialist operator training is not required.
The system is self-cleaning, no solvents are required. After each test, you simply replace the cartridge and the instrument is immediately ready for the next sample.
Enhanced test throughput:
Tests require less than 50 ml of sample and typically take under 20 minutes.
Results are presented in mg/kg units together with an optional traffic light system for flagging FAME contamination levels of the fuel.
By comparison, current analytical tests can take many hours, require complex equipment and demand high skill levels.
Precision and accuracy:
Using a unique sample preparation module the sample is pumped at a controlled flow rate through a proprietary disposable cartridge.
The sample components are analyzed by the FTIR and a result is displayed in mg/kg, a graphical spectrum is also shown.
MEASUREMENT RANGE |
10-150 ppm (mg/kg) FAME in Jet Fuels 20 mg/kg to 20% FAME in Distillate & Residual Fuels |
---|---|
TEST DURATION | 20 minutes |
SAMPLE SIZE | 50 ml |
TEMPERATURE RANGE | 5 to 35°C maximum (80% RH) |
POWER | 150 W maximum |
VOLTAGE | 100/250 V, 50/60 Hz |
SIZE (HXWXD) | 55 x 38 x 42 cm |
WEIGHT | 27 kg |
CCCN CODE | Tariff 90273000 |
Accessories, Spares, Calibration, and Training
-
FIJI ASTM D7963 Annual Service Kit – SA5115-0
-
FIJI Beaker 50 ml (pack of 100) – SA5004-100
-
FIJI Low Lint Wipes (pack of 280) – SA5003-0
-
FIJI DRG Range Extender Diluent 5 L – SA5029-0
-
FIJI ASTM D7963 Cartridges (pack of 100) – SA5105-100
-
FIJI Verification Material 100 ppm, 100 ml – SA5021-0
-
FIJI Verification Material 30 ppm, 100 ml – SA5020-0
-
FIJI Verification Material 900 ppm, 100 ml – SA5123-0
-
FIJI Verification Material 400 ppm, 100 ml – SA5122-0
-
FIJI ASTM D7963 Calibration Material Set – SA5125-0
-
FIJI IP 583 and ASTM D7797 Cartridge (pack of 100) – SA5005-100
-
FIJI IP 583, ASTM D7797 and ASTM D7963 Starter Kit – SA5201-0
-
Pelican™ Storm Case™ for the FIJI – FAME Instruments – CASE-FIJI
-
FIJI Inlet and Outlet Fitting Kit – SA5000-203