Setaflash Series 8 ActiveCool Flash Point Tester – Gas Ignitor and Corrosion Resisting Cup – 82160-2
The Setaflash Series 8 ActiveCool, closed cup flash point tester provides fast and reliable flash point results with a wide temperature range of -30 to 135 °C with no external cooling required.
With the Series 8, a test takes less than 2 minutes with just a 2 or 4ml sample size. A simple user interface with color digital display and touchscreen icons guides you through the straightforward testing process. For easy record keeping, the instrument stores 100,000 test results which can be saved and transferred via a USB port.
Designed for precise and accurate tests, barometric pressure is measured by an internal barometer and correction is automatically applied to the test result. Unknown samples can be tested using ramp mode.
Methods: ASTM D1655, ASTM D3278, ASTM D3828, ASTM D7236, ASTM D8174, ASTM E502, IP 523, IP 534, IP 602, BS EN ISO 3679 & BS 2000-523, CLP REGULATIONS EC NO 1272/2008, EPA 1020 B, ISO 3679
Features
- Simple test procedure
- Compact, rugged design
- Gas ignition
- Automated flash detection
- Ramp mode for unknown samples
- Automatic barometric pressure correction
- Peltier heating and cooling
- Fire detection (alarm and relay)
- USB port and result storage
Ease of use:
All functions on the Series 8, including test parameters, instrument status, and test results are accessed via the touchscreen display. An audible prompt sounds when a flash is achieved, and an automatic flash detector enhances repeatability.
Safety:
Peltier cells prevent the instrument from overheating, whilst a fire sensor immediately stops the test and cools the sample cup if a fire is detected.
Calibration and verification:
Calibration of the Series 8 can be performed in the field, eliminating the costs and time associated with sending the instrument to a service center.
Service and maintenance:
The rugged design ensures minimal operational maintenance is needed.
Supplied with: 2 ml syringe, 99878-3 CRM, Allen keys, mains lead, and instruction manual.
TEMPERATURE RANGE | -30 to 135 °C |
---|---|
TEMPERATURE SELECTION | °C or °F |
IGNITOR | Gas |
HEATING/COOLING METHOD | Peltier cell |
TEMPERATURE RAMP MODE | Automatic or custom settings (ramp rate up to 10 °C/min) |
SAMPLE CUP MATERIAL | Stainless Steel |
PRESSURE CORRECTION | Automatic |
DATA STORAGE | 12 GB |
VOLTAGE | 110 to 250 Vac, 50/60 Hz |
SIZE/WEIGHT | 300 x 340 x 380cm / 8 kg |
CCCN CODE | Tariff 90268020 |
Accessories, Spares, Calibration, and Training
-
Pelican™ Storm Case™ for the Setaflash Series 8, CASE-SERIES8
-
Seta Solid Sample Dispenser – 13747-0
-
Syringe 4 ml (Small Scale Flash Point Instruments) – 13770-311
-
Syringe 2 ml (Small Scale Flash Point Instruments) – 13740-009
-
Small Scale Certified Flash Point Material (50 ml) – 99878-3
-
Insulating Lid – 82103-2
-
Serial Printer – 80602-0
-
Flash Detector for Series 8 – 82000-201
-
Sample Well O-ring, Viton (Pack of 5) – 13740-004
-
Printer Paper (Pack of 20) – 80602-001
-
Portable Digital Barometer – 99910-2
-
Lid and Shutter Assembly – 70000-001