VariRef – Refractometer - 32001

VariRef² I Full-range Refractometer

Full-range Refractometer

Our state-of-the-art refractometer delivers highest precision measurements throughout the entire product lifecycle. The VariRef allows multi-point calibration for the most complete measurement range, thus giving you the tools for a fast and economic maintenance at your side. With the VariRefs’s rapid temperature control and adjustable sample compartment, both liquid and solid samples can be measured. All instruments of our VariFamily are connectable to web browsers, e.g. Google Chrome, on your favorable device, smartphone, tablet, or personal computer.

Pharma-ready module with 21 CFR Part 11 compliance is available, including all documents, options, and methods.

Features

  • Liquid and solid samples
  • Modular and connectable to network
  • Multi-point calibration for full measurement range
  • User friendly
  • Fast temperature control, rapid measuring results
  • Easy cleaning
  • Maintenance free
  • 21 CFR Part 11 conform
  • ELN; LIMS ready

Details

The new user-friendly Aquisys3 software can be accessed either using a 7” user interface or remote via Google Chrome on your favorite device, smartphone, tablet or personal computer. As part of the VariFamily the VariRef2 can be used from different users simultaneously, enabling lab managers to handle and sign data, while lab technicians are still measuring.

The VariRef² series comprises the following modules: VariRef² 301, VariRef² 401, VariRef² 501, and VariRef² 601.

Easy to use
The VariRef² combines proven SCHMIDT + HAENSCH technology with the modularity of the VariFamily. The new double isolated peltier systems allows fast temperature control and reduces the influence of environment temperature, resulting in rapid and precise measurements. The VariRef² has the well-established SCHMIDT + HAENSCH sample chamber. Its flat shape is ideal for easy cleaning. Different sample chamber covers for liquids and solid samples makes it possible to adapt the device to your application. When dealing with hard-to-clean or hazardous materials we offer a special covered version to ensure a long and reliable product lifespan.

Applications
SCHMIDT + HAENSCH refractometers can be used for purity investigations, sample recognition, dilution control or composition. They are also used for characterization of substances or for determination of substance composition, especially of organic liquids or raw materials. With different sample chamber compartment doors it is also possible to measure solid samples which makes it also suitable for other applications, such as quality control of optical films, glass or fibers. Refractometers are also widely used in food, oil, fuel, and other industries to measure and monitor the concentration of components throughout the fabrication process.

Specifications

VariRef 301VariRef 401VariRef 501VariRef 601
Measurement scalesRefractive Index (RI), Sucrose (Brix), Standard scales included,
up to 1000 scales freely definable
Refractive Index (RI), Sucrose (Brix), Standard scales included,
up to 1000 scales freely definable
Refractive Index (RI), Sucrose (Brix), Standard scales included,
up to 1000 scales freely definable
Refractive Index (RI), Sucrose (Brix), Standard scales included,
up to 1000 scales freely definable
Measuring ranges1.3200 – 1.5800 RI / 0 – 100 Brix1.30000 – 1.66000 RI / 0 – 100 Brix1.27000 – 1.71000 RI / 0 – 100 Brix1.27000 – 1.72000 RI / 0 – 100 Brix
Accuracy± 0.0001 RI / ± 0.05 Brix± 0.00003 RI / ± 0.02 Brix± 0.00002 RI / ± 0.015 Brix± 0.00002 RI / ± 0.015 Brix
Reproducibility (Precision)± 0.0001 RI / ± 0.05 Brix± 0.00001 RI / ± 0.01 Brix± 0.000005 RI / ± 0.006 Brix± 0.000005 RI / ± 0.006 Brix
Resolution0.0001 RI / 0.05 Brix0.00001 RI / 0.01 Brix0.000001 RI / 0.001 Brix0.000001 RI / 0.001 Brix
Temperature controlIntegrated peltier sample temperature control systemIntegrated peltier sample temperature control systemIntegrated peltier sample temperature control systemIntegrated peltier sample temperature control system
Temperature control range5 °C to 80 °C5 °C to 80 °C5 °C to 100 °C
Temperature stabilization time25 °C to 20 °C, ±0.1 °C, in 1 minute
(valid for ambient temp. = 20 °C)
25 °C to 20 °C, ±0.1 °C, in 1 minute
(valid for ambient temp. = 20 °C)
25 °C to 20 °C, ±0.1 °C, in 1 minute
(valid for ambient temp. = 20 °C)
25 °C to 20 °C, ±0.1 °C, in 1 minute
(valid for ambient temp. = 20 °C)
Automatic temperature compensationAutomatic temperature compensation for Brix according to ICUMSA and other measuring scales with temperature compensationAutomatic temperature compensation for Brix according to ICUMSA and other measuring scales with temperature compensationAutomatic temperature compensation for Brix according to ICUMSA and other measuring scales with temperature compensationAutomatic temperature compensation for Brix according to ICUMSA and other measuring scales with temperature compensation
Temperature sensor4-wire Pt1000 sensor for measurement of sample temperature placed inside the prism4-wire Pt1000 sensor for measurement of sample temperature placed inside the prism4-wire Pt1000 sensor for measurement of sample temperature placed inside the prism4-wire Pt1000 sensor for measurement of sample temperature placed inside the prism
Temperature sensor accuracy / resolution0.1 °C / 0.01 °C0.1 °C / 0.01 °C0.1 °C / 0.01 °C0.1 °C / 0.01 °C
Ambient temperature5 °C to 40 °C5 °C to 40 °C5 °C to 40 °C5 °C to 40 °C
Minimum sample volume600 µL, with insert for micro volume: < 10 µL600 µL, with insert for micro volume: < 10 µL600 µL, with insert for micro volume: < 10 µL600 µL, with insert for micro volume: < 10 µL
Sample compartment / wetted partsSapphire, FFKM, 1.4404 Stainless Steel (Hastelloy on request)Sapphire, FFKM, 1.4404 Stainless Steel (Hastelloy on request)Sapphire, FFKM, 1.4404 Stainless Steel (Hastelloy on request)Sapphire, FFKM, 1.4404 Stainless Steel (Hastelloy on request)
Housing materialAluminiumAluminiumAluminiumAluminium
Interfaces / CommunicationEthernet, RS232, USB (Type A), WLAN (by WLAN adapter)Ethernet, RS232, USB (Type A), WLAN (by WLAN adapter)Ethernet, RS232, USB (Type A), WLAN (by WLAN adapter)Ethernet, RS232, USB (Type A), WLAN (by WLAN adapter)
DimensionsWith display: 310 x 220 x 250 mm (w x d x h);
without display: 310 x 220 x 150 mm (w x d x h)
With display: 310 x 220 x 250 mm (w x d x h);
without display: 310 x 220 x 150 mm (w x d x h)
With display: 310 x 220 x 250 mm (w x d x h);
without display: 310 x 220 x 150 mm (w x d x h)
With display: 310 x 220 x 250 mm (w x d x h);
without display: 310 x 220 x 150 mm (w x d x h)
Weight5.5 kg5.5 kg5.5 kg5.5 kg
SoftwareAquisys3 Premium / Aquisys3 Premium PharmaAquisys3 Premium / Aquisys3 Premium PharmaAquisys3 Premium / Aquisys3 Premium PharmaAquisys3 Premium / Aquisys3 Premium Pharma
DisplayOptional: 7″ TFT Touchscreen, 800 x 480 Pixel, 16 Bit colorsOptional: 7″ TFT Touchscreen, 800 x 480 Pixel, 16 Bit colorsOptional: 7″ TFT Touchscreen, 800 x 480 Pixel, 16 Bit colorsOptional: 7″ TFT Touchscreen, 800 x 480 Pixel, 16 Bit colors
Conformity / StandardsInternational Pharmacopoeia, ASTM, AOAC, DIN, FDA, ICUMSA and othersInternational Pharmacopoeia, ASTM, AOAC, DIN, FDA, ICUMSA and othersInternational Pharmacopoeia, ASTM, AOAC, DIN, FDA, ICUMSA and othersInternational Pharmacopoeia, ASTM, AOAC, DIN, FDA, ICUMSA and others
Peripherals / OperationOptional: Keyboard, Mouse, Barcode Reader, Remote via PC/Tablet/SmartphoneOptional: Keyboard, Mouse, Barcode Reader, Remote via PC/Tablet/SmartphoneOptional: Keyboard, Mouse, Barcode Reader, Remote via PC/Tablet/SmartphoneOptional: Keyboard, Mouse, Barcode Reader, Remote via PC/Tablet/Smartphone