Glass Flask 500 ml B24 Cone – 24401-0
500 ml glass flask.
Inner diameter: 24 mm
Showing 241–256 of 641 results


For use with Seta oxidation baths (15400-5, 15550-3 and 16670-0).



Consisting of a glass sinker including, platinum wire and sinker hook.
For use with the Air Release Value System (15840-0).

Glass sample tubes for polarimeters
Glass sample tubes are available for single measurements and come with a standard bubble trap for bubble-free filling.
Choose between simple or center filling. The central filling cup allows easy filling and emptying of the tube. Air bubbles escape through the filler opening when moved slightly.
Polarimeter tubes of SCHMIDT+HAENSCH are designed for different applications. All tubes meet the ICUMSA recommendations, class A (±0.01%) and the corresponding specifications of the O.I.M.L. and the Australian Standard K 157 regarding construction and precision. In general: Longer measuring tubes are more reliable than short ones. Sample heterogeneity and residues from previous samples have a larger influence on the accuracy of the
measurement when applying shorter tubes. Larger sample volumes ensure more stability. An exception is the case of
dark samples; a shorter measuring tube might be necessary due to the high absorption of light.
Please consider that SCHMIDT+HAENSCH guarantees the precision of polarimeters only if SCHMIDT+HAENSCH measuring tubes are used.

For use with the vented stoppers used in the Silver Corrosion test kit. Designed to be inserted in the 3.2 mm hole in the stoppers to prevent pressure build up.

1000 ml graduated cylinders for use with the SetaFoam Dual Twin Foam Test Baths (14020-8).

For use with;
Seta Cloud and Pour Point Cryostat (93531-7)
Seta Compact Cloud and Pour Point Cryostat (94100-3)

The rig is a compact bench-top instrument, used to prepare specimens in accordance with the test methods listed.
For use with the Seta Rust Prevention Test Bath (11200-8).

Airflow calibration and verification kit for use with the H2S Analyser.
Supplied with;
Calibrated flowmeter
Stand for flowmeter
1 m silicone tubing
H2S airflow calibration is required monthly.

Calibration kit for use with the H2S Analyser.
Supplied with;
Calibrated thermometer
Temperature calibration equipment (test block and insulation)
Temperature calibration is required every 6 months.

Consumables kit for use with the H2S Analyser.
Supplied with;
5 x test vessels
8 x 500 ml diluent
8 x nylon filters
200 x VPP cartridges
200 x 10 ml syringes
Silicone tubing

Crude oil test kit for use with the H2S Analyser (SA4000-3) to test crude oil samples in accordance with ASTM D7621, appendix X1. The kit allows the test vessel to be mounted outside the heater jacket.
Supplied with;
Positive displacement pipette (10-100µL)
Pipette tips (pack of 192)

Pack of 5 liquid traps or use with the H2S Analyser.

Personal protector for use with the H2S Analyser to provide you with additional safety. The H2S personal protector alerts you if H2S levels exceed breathable safety limits. They are fast, accurate, reliable and easy-to-use personal single gas detectors.
The H2S personal protector is extremely robust and features clear warning signals and language-free displays. The cutting-edge sensor technology delivers reliable results every time and has a two year operational lifespan.
Office:
12692 Sandy Drive
Suite 116
Granger, IN 46530