Setaflash CCC Continuously Closed Cup Flash Point Tester - 35600-0

Setaflash CCC Continuously Closed Cup Flash Point Tester – 35600-0

The Setaflash CCC Continuously Closed Cup Flash Point Tester is an automatic flash point analyser designed for fast, accurate and repeatable determination of flash point using minimal sample volumes. Engineered for safety, efficiency and compliance, it is ideally suited to laboratories testing fuels, lubricants, biodiesel, sustainable aviation fuels (SAF), solvents and chemicals.

The Setaflash CCC combines low sample volume closed cup flash point testing with advanced automation, making it a reliable alternative to traditional large-sample flash point methods.

Automatic Continuously Closed Cup Flash Point Testing

The Setaflash CCC performs continuously closed cup (CCC) flash point testing in full compliance with the methods below.

Methods

ASTM D6450, ASTM D7094, IP 620

Features

  • Wide temperature range in a single model
  • Removable cup, easy to clean
  • Unique automatic magnetic stirrer detection
  • Built-in Peltier cooling
  • Optional external chiller connection
  • Built-in fire extinguisher
  • Emergency stop button
  • Statistical Quality Control software

Details

  • Designed for operator safety:
  • Safety is fundamental to closed cup flash point testing. The Setaflash CCC includes multiple layers of protection:
  • Optical fire detection with automatic inert gas deployment
  • Built-in fire extinguisher, with manual activation available at any time
  • Pre-test safety arcs warn of ignition risks with highly volatile samples
  • Over-temperature cut-out protects the instrument from unsafe conditions
  • Independent emergency stop button can be positioned at a safe distance from the instrument
  • These features provide confidence when testing volatile or hazardous samples in busy laboratory environments.
  • Precision, accuracy and compliance:
  • As an automatic flash point tester, the Setaflash CCC minimises operator influence and ensures consistent results through:
  • Fully automated flash point determination
  • Automatic barometric correction using an internal pressure sensor
  • Password-protected calibration mode for performance verification
  • Magnetic stirrer detection to confirm correct test conditions
  • Statistical Quality Control (SQC) for monitoring repeatability, mean, standard deviation and compliance with ASTM D6299
  • This ensures confidence in results while supporting laboratory accreditation requirements such as ISO 17025.
  • High throughput flash point testing
  • To maximise laboratory productivity, the Setaflash CCC includes:
  • Quick Test function that pre-heats the instrument before sample introduction
  • Rapid Peltier-assisted cooling after each test
  • Customisable test profiles, eliminating repeated data entry
  • Easy-to-clean removable cup, reducing turnaround time between samples
  • Together, these features allow faster testing without compromising accuracy or safety.
  • Intuitive touchscreen operation
  • All routine functions are accessed through a large industrial colour touchscreen allowing operators to:
  • Enter test parameters quickly
  • Monitor real-time test progress
  • View graphical results and trends
  • Export data to LIMS, USB, network or QR code
  • Optional VNC remote access allows viewing results and instrument setup from a connected PC.
  • Why choose the Setaflash CCC?
  • Trusted Stanhope-Seta flash point expertise
  • Fully compliant continuously closed cup methodology
  • Minimal sample volume reduces risk and waste
  • Advanced safety features as standard
  • Designed for modern, accredited laboratories

Specifications

Temperature range-5 °C to 420 °C -15 °C to 420 °C with external chiller
Ignition systemElectric arc
Flash detectionPressure increase = 20 kPa
Ramp rate5.5 °C (ASTM D6450) 2.5 °C (ASTM D7094)
Fire detectionOptical
Sample size1 mL (ASTM D6450 (test cup available as an accessory)) 2 mL (ASTM D7094 (test cup included))
Cooling methodPeltier (liquid cooled with chiller)
StirrerMagnetic with detection
Units of temperature°C or °F (user selectable)
Barometric pressure correctionAutomatic correction with built-in pressure sensor
Voltage110/240 VAC, 50/60 Hz, Auto-sensing universal power supply
Power200 W
Size (HxWxD)43 x 24.9 x 32 cm
Weight16.3 kg