Aromatics Content Reference Material

Flash Point Certified Reference Materials and Standards

Flash point certified reference materials and standards used to verify the performance of flash point instruments and ensure the accuracy of flash point testing. These materials have a known and certified flash point for confirming the reliability of test results for use with Abel, Cleveland Open Cup, Pensky-Martens Closed Cup and Tag flash point instruments.

Abel Closed-Cup Flash Point Certified Reference Materials and Standards

ISO 17034 Abel Closed-Cup Flash Point Certified Reference Materials (CRM) intended to be used for verification of measuring equipment, method validation, method verification, or other quality control processes used to determine flash point, applicable for the test method IP 170, or test methods ISO 13736, and BS 2000 : Part 170, where applicable.

ISO 17034 Abel Flash Point Certified Reference MaterialARO’s Abel Closed-Cup Flash Point Certified Reference Materials have been characterised in accordance with IP 170 or equivalent test method. Manufacturing, testing and certification has been performed in accordance with ARO’s accreditation to ISO 17034, UKAS CAB No. 27393.

ImagePart numberCertified valueCertificationTest methodMatrixPack size
Aromatics Content Reference Material
CRM-ABKR0140.7 °CISO 17034IP 170Jet Fuel250 mL

Cleveland Open Cup (COC) Flash Point Certified Reference Materials and Standards

IISO/IEC 17025 and ISO 17034 Cleveland Open Cup (COC) Flash Point Certified Reference Materials (CRM) intended to be used for verification of measuring equipment, method validation, method verification, or other quality control processes used to determine flash point, applicable for the test method ASTM D92, or test methods IP 36, ISO 2592, or other applicable methods.

ISO 17025 & ISO 17034 Cleveland Open Cup (COC) Flash Point ARO’s Cleveland Open Cup (COC) Flash Point Certified Reference Materials have been characterised in accordance with ASTM D92 or equivalent test method. Manufacturing, testing and certification has been performed in accordance with ARO’s accreditation to ISO/IEC 17025 and ISO 17034, UKAS CAB No. 27393.

ImagePart numberCertified valueCertificationTest methodMatrixPack size
Aromatics Content Reference Material
CRM-FCLU01255.6 °CISO 17025 / ISO 17034ASTM D92Lubricant250 mL
TAN001/3 Total Acid Number (TAN)
CRM-COC1087.9 °CISO 17025 / ISO 17034ASTM D92Mineral Oil3 x 80 mL
TAN001/3 Total Acid Number (TAN)
CRM-COC20123.4 °CISO 17025 / ISO 17034ASTM D92Mineral Oil3 x 80 mL
TAN001/3 Total Acid Number (TAN)
CRM-COC30153.0 °CISO 17025 / ISO 17034ASTM D92Mineral Oil3 x 80 mL
TAN001/3 Total Acid Number (TAN)
CRM-COC40255.5 °CISO 17025 / ISO 17034ASTM D92Mineral Oil3 x 80 mL

Pensky-Martens Closed Cup (PMCC) Flash Point Certified Reference Materials and Standards

ISO/IEC 17025 and ISO 17034 Pensky-Martens Closed Cup (PMCC) Flash Point Certified Reference Materials (CRM) intended to be used for verification of measuring equipment, method validation, method verification, or other quality control processes used to determine flash point, applicable for the test method ASTM D93, or test methods IP 34, ISO 2719, or other applicable methods.

ISO 17025 & ISO 17034 Pensky-Martens Closed Cup (PMCC)Flash Point ARO’s Pensky-Martens Closed Cup (PMCC) Flash Point Certified Reference Materials have been characterised in accordance with ASTM D93 Procedure A, Procedure B, or equivalent test method. Manufacturing, testing and certification has been performed in accordance with ARO’s accreditation to ISO/IEC 17025 and ISO 17034, UKAS CAB No. 27393.

ImagePart numberCertified valueCertificationTest methodMatrixPack size
TAN001/3 Total Acid Number (TAN)
CRM-PMCC1078.1 °CISO 17025 / ISO 17034ASTM D93Mineral Oil3 x 80 mL
TAN001/3 Total Acid Number (TAN)
CRM-PMCC20109.2 °CISO 17025 / ISO 17034ASTM D93Mineral Oil3 x 80 mL
TAN001/3 Total Acid Number (TAN)
CRM-PMCC30139.9 °CISO 17025 / ISO 17034ASTM D93Mineral Oil3 x 80 mL
TAN001/3 Total Acid Number (TAN)
CRM-PMCC40232.4 °CISO 17025 / ISO 17034ASTM D93Mineral Oil3 x 80 mL
Aromatics Content Reference Material
CRM-PMGO0161.5 °CISO 17025 / ISO 17034ASTM D93Diesel250 mL
Aromatics Content Reference Material
CRM-PMLU01107.3 °CISO 17025 / ISO 17034ASTM D93Lubricant250 mL

Tag Closed Cup Flash Point Certified Reference Materials and Standards

ISO 17034 Tag Closed Cup Flash Point Certified Reference Materials (CRM) intended to be used for verification of measuring equipment, method validation, method verification, or other quality control processes used to determine flash point, applicable for the test method ASTM D56, or other applicable methods.

ISO 17034 Tag Closed Cup Flash Point Certified Reference MaterialARO’s Tag Closed Cup Flash Point Certified Reference Materials have been characterised in accordance with ASTM D56 or equivalent test method. Manufacturing, testing and certification has been performed in accordance with ARO’s accreditation to ISO 17034, UKAS CAB No. 27393.

ImagePart numberCertified valueCertificationTest methodMatrixPack size
Aromatics Content Reference Material
CRM-TAKR0139.4 °CRound RobinASTM D56Jet Fuel250 mL