PFXi-880/P – 1378803
Color Measurement for Fuels & Waxes
- Integrated RCMSi Technology for Remote Calibration
- Optional Heater Keeps Samples Above The “Cloud Point” (PFXi-880 – 1378803H)
- Automatic and Non-subjective Colour Measurement
- Unique Long Path Length Chamber – Accommodates up to 6″/153mm Cells
The PFXi series of spectrophotometric colorimeters introduces a unique concept in liquid color control: RCMSi technology. You can benefit from the capability for remote calibration and servicing via the internet – saving the cost and time associated with servicing and guaranteeing compliance with standards.
The PFXi-880/950/995 series ensure high-precision results from the 16-filter wavelength technology. With an extended path length capacity of up to 6″ (153 mm) and an optional heater to sustain the temperature of the sample to +10°C above its “cloud point,” they meet the demand for consistent and reliable color data for a wide range of samples.
Applications
Petroleum Oils and Waxes
Methods: ASTM D156, ASTM D1500, ASTM D6045, ASTM E308, ISO 2049
- Integrated RCMSi Technology for Remote Calibration
The PFXi series of spectrophotometric colorimeters introduces a unique concept in liquid color control: RCMSi technology (Remote Calibration & Maintenance Service via the Internet). You can now benefit from the capability for remote calibration and servicing via the Internet – eliminating any costs and time delays associated with servicing and guaranteeing compliance with standards.Watch the RCMSi video to see how easy the procedure is.
- 153mm (6″) Sample Chamber
The long path length cell chamber enables you to measure extremely unsaturated, light samples and color scales, which are defined with long path lengths, including the Lovibond® RYBN and AOCS Tintometer® color, guaranteeing compliance with AOCS, ISO, and ASTM standards. - Optional Integrated Heater Unit
The PFXi-880, -950 & -995 series are available with an optional integrated heater unit. This is a critical feature when dealing with materials such as fats and waxes whose temperature needs to be maintained at a constant temperature +10°C above the “Cloud Point” of the material. - 16 Wavelength Filters
Ensure high precision, accurate spectral data. - Automatic and Non-subjective Colour Measurement
The PFXi range provides absolute results. Automatic instruments communicate in clear terms, accurately, and reliably with no opportunity for human error or misjudgment. - Consistent Data Compliant with International Standards
The PFXi range automatically measures color and displays results directly, either according to the traditional grading scales that have been widely adopted as industry standards for color assessment and control, or in terms of internationally recognized CIE values and spectral data. - Very Rugged, Chemically Resistant, Steel Construction
The robust steel construction enables you to use the PFXi even in the harshest of environments. - Easy Maintenance with Removable Sample Chamber
The instruments include a robust steel sample chamber which is easily removed so you can clean it or replace it should spillage occur. - Extensive and Flexible Choice of Colour Scales
You can choose from a selection of over 20 different, internationally recognized scales in a variety of combinations. - Remote Upgrade Facility
Uniquely, however, you do not need to make the choice of scales at the point of purchase. The PFXi instruments are upgradeable in the field – so you can add a scale at a later date. - Calculation and Description of “Off-Hue” Status
This is a useful facility that enables you to reveal whether the sample color is characteristic of the selected scale. Where appropriate, it includes a description of hue difference (e.g., redder, greener), relative saturation (stronger or weaker), and an off-hue factor (a relative measure of the distance away in color space of the sample color from the “true” color scale). - Supplied with Colour Control Software for Data Analysis
The software allows you to generate spectral and CIE diagrams as well as analyze spectral data. It also permits direct control of the instrument from the computer. - Conformance Standard, Cells, and Spare Bulb Included
For regular conformance checking, certified color reference standards are also available for routine calibration and verification of test data. Conformance filters are supplied with a Certificate of Conformity – giving you the assurance of their color values and confirmation that they were manufactured under the control of The Tintometer Ltd’s ISO 9001 quality system. - Output Conforming to GLP Including Date, Time, Sample & User ID
The adaptable software and design allow you to configure the PFXi to your requirements. You can set the display language, program the instrument to only display the scales of interest, and restrict access to the menu system. - Accommodates a Wide Range of Sample Cells and Tubes
As well as standard colorimetry cells, the PFXi-880/950/995 series can be used with a range of tubes and standards, flow-through, and disposable spectrophotometer cells. - Extensive range of accessories
A thermal printer, sample chamber, additional cells, replacement lamps, and conformance filters represent some of the additional accessories you can obtain for the PFXi Series.
Applicable Standard | ASTM D156 ASTM D1500 ASTM D6045 ASTM E308 ISO 2049 |
Color Type | Transparent |
Measuring Principle | 16 interference filters |
Detector | blue enhanced photodiode |
Display | 240 x 128, back-lit graphic display, (white on blue) |
Interfaces | USB RS 232 Ethernet |
Path Length | 0.1 – 153 mm (0.004″ – 6″) |
Measuring Geometrics | 0° – 180° transmission |
Internal Storage | 100,000+ Measurement |
Measurement Time | less than 30 seconds |
Power Supply | Universal (90 – 240 VAC), via external power supply |
Spectral Range | 420 – 710 nm |
Bandwidth | 10 nm |
Illuminants | CIE Illuminant A CIE Illuminant B CIE Illuminant C CIE Illuminant D65 |
Portability | Benchtop |
Observer | 2°, 10° |
Compliance | CE RoHS WEEE |
Languages User Interface | English, French, German, Italian, Portuguese, Russian, Spanish, Chinese, Japanese |
Dimensions | 515 x 170 x 196 mm |
Title | Scale Path Length | Scale Range | Scale Resolution | Applicable Standard |
---|---|---|---|---|
ASTM Colour | 33 mm | 0 – 8 | 0.1 unit | ASTM D6045 |
Saybolt Colour | 100 mm | -16 – +30 | 1 unit | ASTM D156, ASTM D6045 |
CIE L* a* b | 1 mm – 6″ | dependant on spectral locus | 0.01 | ASTM E308 |
Delta E* color difference | dependant on spectral locus | 0.01 | ||
Optical Density | 1 mm – 6″ | 0 – 2.5 | 0.0001 | |
Transmission % | 1 mm – 6″ | 0 % – 100 % | 0.1 % | |
xyY chromaticity co-ordinates | 1 mm – 6″ | 0 – 1 (x,y), 0 – 100 (Y) | 0.0001 (x,y), 0.01 (Y) | ASTM E308 |
XYZ Tristimulus | 1 mm – 6″ | 0 – 100 | 0.01 | ASTM E308 |
- PFXi Series Instrument
- External Power Supply
- Set of 3 Power Leads (UK, European, and United States)
- USB and LAN Cable
- Quick Start Guide
- USB Memory Stick (Containing Windows® Control Software and Manuals)
- RCMSi Starter Pack
- Certificate of Conformity
- Accessory Box with 5 Volt Halogen Lamp, Conformance Filter, and W600/B/33 Cell, W600/B/100 Cell
Title | Glass Standard Values | Filters | Part Number |
---|---|---|---|
ASTM Color Filter Set (PFXi995/950/880) |
Approximate Values
|
3 | 139820 |
ASTM Color Filter Set (PFXi195) |
Approximate Values
|
3 | 139810 |
Title | Part Number |
---|---|
ASTM Color <0.5 | 134290 |
ASTM Color 1 | 134000 |
ASTM Color 3 | 134010 |
ASTM Color 5 | 134020 |
ASTM Color 7 | 134030 |
Saybolt Color -10 | 134040 |
Saybolt Color 0 | 134050 |
Saybolt Color +12 | 134060 |
Saybolt Color +25 | 134070 |
Title | Part Number |
---|---|
PFXi Lamp 5V | 138180 |
Replacement Sample Chamber for PFXi 880/950/995 | 133840 |
Holder for standard spectrophotometer cells (12.5 mm width) | 131907 |
Adapter for 10.65 mm tubes | 132800 |
Adapter for 33 mm tubes | 132810 |
Tube, 10.65 mm diameter | 352290 |
Tube, 33 mm diameter for ASTM Color | 352300 |
Dark sample cell for CIE values, 1 mm path length | 132820 |
Flow through control software | 137690 |
Flow through cell, 50 mm path length | 658010 |
Flow through cell, 10 mm path length | 658020 |
PFXi IQ/OQ Documentation | 137680 |
PFXi Thermal Printer | 137891 |
PFXi heater upgrade pack | 137880 |
RCMSi Certified Calibration Pack – Full | 134410 |
RCMSi Certified Calibration Pack – Conformance | 134420 |
RCMSi Certified Calibration Pack – Starter | 134430 |
Acid Wash tube | 131840 |
PFXi Instruction CD including Windows Software | 137460 |
PFXi external power supply pack | 131219 |