Sindie R3 Accucell - 403746-02

Sindie R3 Accucell – 403746-02

Analyze Sulfur with Precision and Flexibility

Sindie R Series analyzers are your trusted sulfur analysis solutions for products ranging from ultra-low sulfur diesel and gasoline to heavy fuel oil and crudes. The differences between our various Sindie analyzers are specific to analytical performance (differing Limits of Detection).

Easier to use than ever, Sindie R3 is our most advanced sulfur analytical solution for compliance with ASTM D2622, ASTM D7039, ISO 20884, and EN 16997 methods, enabling complete flexibility for your analytical needs. Advanced R3 optics provide extremely low limits of detection, allowing for cycle time flexibility to save up to hours per day in testing time. This model utilizes Accucell sample cups for hassle-free sample prep.

Easy to use

Advanced R3 optics provide extremely low limits of detection, allowing for cycle time flexibility and saving up to hours per day in testing time.

  • Extremely low maintenance
  • Total sulfur analysis
  • For use in multiple application areas
  • Hassle-free sample preparation3 Accucell

Methods: ASTM D2622, ASTM D7039, ISO 20884, EN 16997

Easy to use
Advanced R3 optics provide extremely low limits of detection, allowing for cycle time flexibility and saving up to hours per day in testing time
LIMS integration for data management and transfer, intuitive 10-inch touch screen, measurement time 10-999 s, barcode reader auto fills sample name, USB connectivity, storage capacity for more than 50,000 results, supports up to 30 calibration curves.

Extremely low maintenance
No gasses, heating elements, quartz tubes, or columns. Large, easy-to-remove side panels for easy serviceability. Advanced error reporting and diagnostics.

Total sulfur analysis
From ultra-low sulfur diesel and gasoline to heavy fuel oil and crudes to biofuels and chemicals, the analyzer delivers unprecedented precision and accuracy.

For use in multiple application areas
Refinery labs, pipeline terminals, additive plants, testing vans, and inspection laboratories

Hassle-free sample preparation
Utilizes Accucell pre-assembled and pre-vented sample cups for enhanced precision, ease of use, and improved productivity.

Calibration curves:
Supports up to 30 calibration curves. Automatic and manual calibration functionality.

Catalysts: No
Communication Capabilities: USB, Ethernet: LIMS Connectivity
Consumable/Utility Gas: Vacuum
Dimensions: Depth: 21 in / 54 cm
Dimensions: Height: 16.5 in / 42 cm
Dimensions: Width: 15.8 in / 40 cm
Element: Sulfur/ 0.18 ppm
Measurement Time: User selectable 10-999 s
Method Name: ASTM D2622, ASTM D7039, ISO 20884, EN 16997
Options: USB Printer (Receipt or Full Page), Consumables, Calibration Standards, Spare Parts
Range: 0.18 ppm – 10%
Repeatability:
ppm – r
2 – 0.3
5 – 0.5
8 – 0.6
15 – 0.8
100 – 2
500 – 5
Reproducibility:
ppm – R
2 – 0.7
5 – 0.8
8 – 1.0
15 – 1.4
100 – 4
500 – 10
Sample Cup Type: Accucell
Sample Matrix: Hydrocarbon
Specific Technology: MWDXRF
Type: Benchtop
Weight: 75 lbs / 34 kg
What’s included?: Quick-Start Guide, Operations Manual, radiation survey, power cord, 6′ drain tubing, spare fan filter, spare fuse, 100 Accucell Mylar Sample Cups (490002-01), sample stand, spare primary window and one calibration set, D7039 and D2622 S in Mineral Oil calibration sets. Printer optional.
XRF Film Type: Mylar