Setaflash Series 8 Closed Cup Flash Point Tester – High Temperature - 82000-2

Setaflash Series 8 Closed Cup Flash Point Tester – High Temperature – 82000-2

The Setaflash Series 8 closed cup flash point tester provides fast and reliable flash point results with a wide temperature range from ambient to 300 °C with no external cooling required.

With the Series 8, a test takes less than 2 minutes with just a two or 4ml sample size. A simple user interface with a color digital display and touchscreen icons guides you through the straightforward testing process. For easy record keeping, the instrument stores test results, which can be saved and transferred via a USB port to a laboratory information management system (LIMS).

Designed for precise and accurate tests, barometric pressure is measured by an internal barometer and correction is automatically applied to the test result. Unknown samples can be tested using ramp mode.

Methods: ASTM D1655, ASTM D3278, ASTM D3828, ASTM D7236, ASTM D8174, ASTM E502, IP 523, IP 524, IP 534, IP 602, BS EN ISO 3679 & BS 2000-523, CLP REGULATIONS EC NO 1272/2008, EPA 1020 A & B, ISO 3679, ISO 3680 (OBS), ISO 9038

Features

  • Simple test procedure
  • Compact, rugged design
  • Electric ignition
  • Automated flash detection
  • Ramp mode for unknown samples
  • Statistical quality control system
  • Automatic barometric pressure correction
  • Fire detection (alarm and relay)
  • USB port and result storage

Ease of use:
All functions on the Series 8, including test parameters, instrument status, and test results are accessed via the touchscreen display. An audible prompt sounds when a flash is achieved, and an automatic flash detector enhances repeatability.

Safety:
A fire sensor immediately stops the test and cools the sample cup if a fire is detected.

Statistical quality control:
The statistical quality control (SQC) analysis feature allows you to analyze the results of previous tests, calculate mean, standard deviation, standard error, and repeatability, and plot results in accordance with ASTM D6299. You can analyze all the results stored or selected results.

Calibration and verification:
Calibration of the Series 8 can be performed in the field, eliminating the costs and time associated with sending the instrument to a service center.

Service and maintenance:
The rugged design ensures minimal operational maintenance is needed.

Supplied with: 2 ml syringe, 99878-3 CRM, Allen keys, mains lead, and instruction manual.

TEMPERATURE RANGE Ambient to 300 °C
TEMPERATURE SELECTION °C or °F
IGNITOR Electric
HEATING/COOLING METHOD Ceramic hotplate and fan
TEMPERATURE RAMP MODE Automatic or custom settings (ramp rate up to 10 °C/min)
SAMPLE CUP MATERIAL Aluminium
PRESSURE CORRECTION Automatic
DATA STORAGE 12 GB
VOLTAGE 110 to 240 Vac, 50/60 Hz auto-sensing power supply
SIZE (HXWXD) 300 x 340 x 380 mm
WEIGHT 8 kg
CCCN CODE Tariff 90268020