Seta C-92 – 35300-0

Seta C-92 Automatic Cleveland Flash Point Tester – 35300-0

The Seta C-92 Cleveland open cup Flash and Fire point tester is an automatic bench-top instrument, used to determine flash point and fire point temperatures of products at temperatures up to 400 °C.

The C-92 is controlled through a large color touchscreen and allows test progress and results to be viewed from across the laboratory if required.

The instrument incorporates a heater, a removable test cup, interchangeable gas, and electric hot-wire ignitors mounted on an automatic sweep arm, a platinum resistance thermometer (PRT) to measure the sample temperature, an ionization ring to detect a flash/fire, a snuffer, and a fire extinguisher. A draught screen around the test area ensures accurate results.

An automatic snuffer deploys to extinguish the burning sample at the end of a test and an optical fire sensor provides next-level safety.

C-92 Statistical Quality Control (SQC) software provides detailed analysis of test results, calculated mean, standard deviation, standard error, repeatability, and plot of results in accordance with ASTM D6299 Statistical Standard.

Methods: ASTM D92, ASTM D8254, IP 36, AASHTO T48, DIN 51 376, ISO 2592, JIS K2265, NF T60-118

Features

  • Easy operation
  • Superior safety
  • Gas or electronic ignition
  • Real time display of test progress
  • Unique test profiles
  • Large touch screen
  • Rapid cooling system
  • Automatic snuffer and fire extinguisher
  • Large memory storage
  • Statistical Quality Control Software

Operator safety:
Snuffer automatically deploys when the test ends to extinguish the burning sample
Snuffer can be manually deployed at any time
Optical fire sensor provides another level of fire protection, inert gas is deployed around the cup and cup area if persistent fire is detected
If the sensor detects a fire at any other time or it is not extinguished by the snuffer, the fire extinguisher deploys
Additional safety features include over-temperature cut-out, optional safety sweeps, gas shut off and emergency stop

Ease of use:
Intuitive user menu with color touchscreen operation
Real-time display of test progress
Large capacity memory allows storage of test profiles, operator names, test methods, and results
Test status and results are graphically displayed
Data format is compatible with most PC/LIMS spreadsheets, and a USB port allows results to be saved to portable memory devices
QR code data transfer

Enhanced test throughput:
Bespoke test profiles enable the test to be set up and repeated quickly without re-entering the same information
Snuffer plate and ionization ring are quickly and easily removed for cleaning to minimize downtime between tests
Built-in cooling system helps maximize test efficiency by rapidly cooling the cup at the end of the test, allowing the next test to start as soon as possible

Precision and accuracy:
Fully automated test process ensures repeatability and reproducibility
On-board barometer automatically corrects test results for variations in atmospheric pressure
Draught screen around test cup for consistency and accuracy of results
Optional rake to remove skin on sample
Password protected ‘calibration’ mode allows verification of instrument performance
SQC software to maintain instrument accuracy and enable product quality monitoring

Supplied with: Cup, Draft shield, mains cable, and instrument handbook.

Ignition system Electric or gas
Flash detection Ionization ring
Fire detection Ionisation ring and optical fire sensor
Cooling Fast forced air (integral fan, adjustable)
Heating rate Adjustable fast heating mode (up to 17 °C/min) and standard rate 5.50 °C/min
Temperature range Ambient to 400 °C
Internal memory More than 7 Gb of storage
Power Maximum 600 W, during typical test <100 W
Voltage 100 V to 240 V, 47 Hz to 63 Hz, autosensing
Size (HxWxD) 240 x 385 x 450 mm
Weight 15.5 kg
CCCN Code Tariff 90268020